To prevent problems use saddles or straps to support at regular intervals 4c 4d follow the manufacturer s instructions but in case they get lost here is a list of best practices for.
How to put 6 inch flexable ducy through floor register.
These can be drywalled easily.
In order for your forced air furnace to work properly you have to have the right sizes of duct vents in each room expelling air.
There are dozens of fittings to connect it around corners to registers and to round pipe used for floor registers.
But without proper support ducts can develops sags or kinks that reduce airflow 4a 4b.
Pull the flexible duct down a couple of inches and insert the end of the register boot into its open end.
As a last resort you may have to put a duct in the corner of a room s.
In this tutorial i am happy to show you how to properly install flexible duct to a register can for all you heating air conditioning ventilation do it your.
I even add so.
I am looking for the air to be pushed out hard so that it creates airflow in the room.
Most registers i size are about the same sq in s as the duct or a little less.
Big rooms with oversized registers can have hot spots away from the register.
Input the required cfm in the box below that.
It comes in 5 inch 6 inch and 7 inch widths so it delivers a lot of air.
The duct vent size will depend on the size of the furnace and the size of your home so you know how many vents you need in each room.
Sometimes the best route for a flexible duct run is up and over an obstruction.
Cutting and attaching flex duct to metal boot.
Now the downside of going to small with your register is that it is too loud.
Click calculate and you will see the size of flex duct you need for that room.
Using just basic tools we will cut flexible ductwork and strap the flex to the round metal boot.
Floor registers are.
Design cfm 4 cfm 6 cfm 8 cfm 10 cfm 12 60 6x4 60 4x6 90 4x8 120 4x10 150 4x12 90 8x4 110 6x6 160 6x8 215 6x10 270 6x12 120 10x4 160 8x6 230 8x8 310 8x10 400 8x12 150 12x4 215 10x6 310 10x8 430 10x10 550 10x12 180 14x4 270 12x6 400 12x8 550 12x10 680 12x12 210 16x4 320 14x6 490 14x8 670 14x10 800 14x12 240 18x4 375 16x6 580 16x8 800 16x10 950 16x12 270 20x4 430 18x6 670 18x8 930 18x10 1100.
Use the online duct calculator see references and calculate the needed flex duct size.
The flex duct size may be different than the hard duct that runs to that room.
The furnace s british thermal units btus will help calculate the size it needs.
Select the duct type on the pull down menu.